Magnetic Separator, currently, has a wide application. But enough attentions should be paid to the starting and pausing of the machine.
(1) Before staring the machine, please make a overhaul examination on the device. Find out the reasons that lead to the failure of the machine. If the machine stops due to mechanical breakdown, we need to shoot the problem before starting the machine. Ensuring all the devices (including electronics) are well checked, then make the trial run of the machine first to make sure the machine runs smoothly and there is no obstruction, which indicates that the machine is normal, or else, making inspection and solve the problems before starting the machine.
(2) Boot the machine, after the machine runs stably then add a magnetic current on it. The voltage cannot be added directly to rated voltage, instead it should be gradually from small to large then. Prohibit to add water into the machine after the machine is running. It is not allowed to add magnetic before starting the machine. It is banned to start the machine with loading. Please feed the mineral material after the machine runs stably and magnetized. Attention! The material that fed in the machine cannot mix with wood slag, material with size over the gap distance of the teeth plate as well as magnetized mineral. Generally, before magnetic separating, we usually adopt weak magnetization to remove magnetized material and then use the screening machine to remove the debris and large granularities to prevent blockage. Besides, the quantity of material feeding should be proper and even.
(3) Please open all the valves of water pines on the machine before staring it. Inspect whether the water mouse has blockage and check the water manometer to see whether the pressure reaches the required level. Before start the oil pump, please make sure the cooling water pipe is open and valves of oil circuits are open. When the oil pump is boosted, please check the oil level to see whether it is under normal level and whether there are leakages in the oil circuits. Please make sure the oil circuit has smooth circulation.
In summary, the right machine starting procedures could be concluded as follow: Make overhaul check on water feeding-starting the lubrication oil pump-boosting cooling pump-then the machine-magnetized the coils-material feeding. While stop the machine, it has two modes that is normal stop and abnormal stop.